Operation and management of refrigeration equipment
1. As the evaporation temperature decreases, the compression ratio of the compressor increases, and the energy consumption per unit cooling capacity increases. When every 1 ℃ below the evaporation temperature, more power consumption 3% - 4%. Therefore, it is possible to reduce the evaporation temperature difference and increase the evaporation temperature, not only saving electricity consumption, but also increasing the relative humidity between the cold.
2. As the condensing temperature increases, the compression ratio of the compressor increases, and the energy consumption per unit cooling capacity increases. Condensation temperature between 25 ℃ and 40 ℃, every increase 1 ℃, increase power consumption by around 3.2%.
3. When the heat exchange surface of the condenser and evaporator is covered with oil layer, the condensation temperature will increase and the evaporation temperature will decrease, leading to the reduction of cooling production and the increase of electricity consumption. When 0.1mm thick oil layer is accumulated on the inner surface of the condenser, the cooling capacity of the compressor will decrease by 16.6 and the electricity consumption will increase by 12.4. Within the evaporator surface product 0.1 mm thick oil reservoir, in order to maintain constant low temperature requirements, evaporation temperature is 2.5 ℃, power consumption increased by 9.7.
4. When the air is concentrated in the condenser, the condensing pressure will increase, and when the non-condensing gas partial pressure reaches 1.96105Pa, the power consumption of the compressor will increase by 18.
5, when the wall form scum of condenser is 1.5 mm, condensation temperature than the scale before the temperature increased 2.8 ℃, power consumption increased by 9.7.
6, evaporator surface covering a layer of frost layer, reduce the heat transfer coefficient, especially when the surface frosting finned tube, not only increase the heat transfer resistance, but also difficult to make the air flow between the fin and reduce the appearance of the heat transfer coefficient and heat dissipation area. When indoor temperature is lower than 0 ℃, 10 ℃ temperature difference on both sides of the evaporator pipe, evaporator work after a month, the heat transfer coefficient is about frost before 70.
7. The gas inhaled by the compressor is allowed to be over-heated to a certain extent, but the over-heat is too high, and the specific volume of the gas inhaled increases, its cooling capacity decreases, and the relative power consumption increases.
8. When the compressor is frosting, quickly close the small air suction valve, sharply reduce the cooling capacity and increase the relative power consumption.
From the above analysis, it can be seen that good operation management of refrigeration equipment is an important link to improve the economic benefits of refrigeration system.
Ii. Energy-saving measures for refrigeration operation
We will strengthen the management of equipment operations and establish a system for electricity management and statistics on single consumption. We will increase the necessary measuring instruments and instruments, carry out energy conservation and technological transformation, and consolidate the work of energy conservation from the system.
1. Properly control and adjust the amount of liquid supplied by the system, and avoid excessive humidity and overheating of the compressor after inhalation.
2. Choose the number of compressor running stations reasonably, so that its refrigeration capacity matches the thermal load of the system.
3. Adjust the number of operating platforms of the fan and water pump according to the process requirements and the change of external temperature.
4. Regularly release oil and air, remove frost and scale, maintain good heat transfer effect of the equipment, and avoid excessive condensation pressure and low evaporation pressure.
3. Improve working conditions of refrigeration equipment
1. Improve the water quality, slow down the scaling, improve the condensing effect of the condenser, and reduce the condensing temperature.
2. When the load rate of motors of refrigeration equipment is lower than 0.4, the motors can be changed from being exposed to Y, so as to improve the power factor. Moreover, it is required to make automatic switching between them.
3. Use automatic control operation instead of manual operation as far as possible, so as to realize the operation of the refrigeration system in the best working condition, which can save 5-15% of electricity.
The last one:The advantages and disadvantages of various chiller are summarized
Next:The role of these components in cold storage construction?

Return list

Recommended for you

  • Mobile web site

  • The official WeChat

版權(quán)所有: 江蘇利邦機電設(shè)備有限公司 Copyright ? 2018 蘇ICP備18027510號-1

主站蜘蛛池模板: 免费又黄又爽又猛的毛片| 亚洲av无码不卡无码国产| 婷婷色婷婷深深爱播五月| 国产美女露脸口爆吞精| 国产色无码精品视频国产| 亚洲综合久久成人a片| 四虎成人精品国产永久免费无码| 亚洲av乱码中文一区二区三区| 欧美怡春院一区二区三区| 国产午夜视频在线观看| 正播国产一区二区视频在线| 日韩在线不卡免费视频一区| 国产成人亚洲综合无码精品| 欧美最猛黑人xxxx| 国产精品久久久久9999| 一本无码av中文出轨人妻| 亚洲大色堂人在线视频| 亚洲国产成人久久久网站| 日本丝袜诱惑一区二区| 久久精品成人无码观看免费| 国产精品激情欧美可乐视频| 88国产精品欧美一区二区三区| 色吊丝永久性观看网站| 男人狂桶女人出白浆视频| 色欲老女人人妻综合网| 老太脱裤子让老头玩xxxxx| а天堂中文在线官网| 亚洲精品久久久久久不卡精品小说| 日本一本免费一区二区三区免| 精品一区二区三区毛片视频网 | 日美韩精品一区二区三区| 久久男人av资源网站| 精品国产乱码久久久久久下载| 疯狂三人交性欧美| 国产亚洲色视频在线| 强奷乱码中文字幕| 极品人妻被黑人中出种子| 亚洲自拍图片一区| 日本成本人片视频免费| 国产人妻人伦精品婷婷| 中文字幕无码不卡一区二区三区|